Royale By Drive Service Manual Page 15
Back-up Lamp Control
ITEM
SPECIFICATION
Operation Feature
Take exterior back-up lamp switch as determinant signal.
(1) Switch on/off the head light by pressing button once, then LED
will turn on/off simultaneously.
(2) LCD backlights turn on / turn off with head light.
(Control Mode)
Brake-lamp Mode
Reversing-lamp Mode
When motor changes from act (go forward) to stop, the lamp reinstated after
flashing for 3 sec.
Determine as “Reversing Mode”, back-up lamp keep flashing.
Reverse warning sound can be set by panel ( Turn on / Turn off)
Usage Condition
While (a) KEY OFF (b) Charging Mode (c) Sleep Mode, all functions closed.
* Brake-lamp & Reversing-lamp Mode won’t be limited by Back-up lamp
switch on or off.
Flicker Frequency
1 sec.
Determinant Condition
(1) 2.2VWIP2.8V ( 50% Half-power )
(2) 2.2VWIP2.8V ( 100% Full-power )
(3) Full / Half power switch at real time.
(4) The determination of “Reversing Mode” need to consider the motor
direction and panel setting.
Remarks
(1) Loop Load : 24V/50W max
(2) With “short circuit” and “overload” protection