Celestia
CPAP with Heated Humidifier
Instruction Manual
Model No.: 18250 Please read the instruction manual before use.
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - Celestia

Celestia CPAP with Heated Humidifier Instruction Manual Model No.: 18250 Please read the instruction manu

Page 2

3.3 WARNING & CAUTION WARNING: This CPAP machine should be used only with special masks (or connectors) recommended by the manufacturer of the

Page 3 - SAVE THESE INSTRUCTIONS

4. Operation NOTE: Always read the operating instruction before use. 4.1 Control Panel Description Buttons arrangement on control panel and main u

Page 4

4.2 Function Description (1) Ramp Time Ramp time function allows user to fall into sleep with a lower, comfortable pressure and helps users graduall

Page 5 - 1. Introduction

(5) Total Meter Press "MENU" button to select [TM XXXX.X hr] menu, the total compliance meter records the total number of hours that the dev

Page 6

4.3 Flowchart of Menu settings Enter the user's menu mode by pressing the “MENU” button. In each setting, when the preferred value has been s

Page 7

4.4 Using the heated humidifier 1. While the device is turned on., the heater power on indicator on the right side of the device will be lit (gr

Page 8 - 3. Installation

5.2 Tubing and Mask The tubing and mask should be checked and cleaned daily. Please refer to the cleaning instruction packaged with the accessories.

Page 9

and may eventually be replaced. Replace the chamber parts if any damage is present. 6. Troubleshooting The table below lists troubleshooting solution

Page 10

Error 001 Error 002 Warn 001 Warn 002 close to mask or flexible tube is low. Water Leakage 1. Assembly of water chamber is not proper or incor

Page 11 - 4. Operation

7. Technical Specifications Item Specifications Power Supply 100-120VAC, 50/60Hz, 0.5A (For 120V system) 220V-240VAC, 50/60Hz, 0.3 A (For 230V syste

Page 12

Contents Important Safeguards…………………..…………….….….….1 1.Introduction…………………………...……………….3 2. Product Description……………….…...…………….…..4 3. Install

Page 13

BF symbol, which indicated this product is according to the degree of protecting against electric shock for type BF equipment. Attention, should r

Page 14 - Down Up Confirm

GROUNDING INSTRUCTIONS This product should be grounded. In the event of an electrical short circuit grounding reduces the risk of electric shock by p

Page 15

Guidance and Manufacturer’s Declaration- Electromagnetic Emissions: This device is intended for use in the electromagnetic environment specified below

Page 16

Immunity Test IEC60601 test level Compliance Electromagnetic Environment-Guidance Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3

Page 17 - 6. Troubleshooting

assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field streng

Page 18

Additional instruction for Physician and Technician (Do not distribute to patients) 1. To Set the Therapy Pressure 1. Press "MENU" to sel

Page 19 - 7. Technical Specifications

Drive Medical Design & Manufacturing 99 Seaview Boulevard Port Washington, NY 11050 516-998-4600 www.drivemedical.com

Page 20 - Air flow direction

IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING WARNING – 1. THIS DEVICE IS NOT INTENDED FOR LIFE SUPPORT. It may s

Page 21 - GROUNDING INSTRUCTIONS

DANGER -To reduce the risk of electrocution: 1. Always unplug this product immediately after using. 2. Do not use while bathing. 3. Do not place or st

Page 22

1. Introduction This manual should be used for initial set up of the system and saved for reference purpose. 1.1 General Information Obstructive

Page 23

2. Product Description Components including: (1) Main CPAP device with integrated heated humidifier (2) Detachable power cord (3) User manual (4)

Page 24

Water Chamber: The water chamber contains the water for humidification. Its removable base plate allows itself ease for cleaning. Fil

Page 25

3. Installation 3.1 Unpacking To secure its contents inside, the device and accessories are bundled in a paper packaged box. Unpack this box by remo

Page 26 - 99 Seaview Boulevard

4) Connect the other end of the air tubing to the mask system. Putting on the mask and headgear according to the mask instruction manual. Daily Use